Problem
Likely Cause
Remedy
Insulation exiting hose is
dribbling out.
Heavy insulation material.
Push slide gate in 1-2 holes.
Kink in hose.
Straighten hose.
Airlock seal is worn.
Inspect airlock seals for cuts and
wear. Have a qualified
technician replace airlock seals.
Blower does not operate.
Worn brushes in blower motor.
Have a qualified technician
replace blower brushes or
replace blower motor.
Agitator does not operate.
Insulation is jamming the
agitator.
Disconnect electrical power.
Remove insulation material from
hopper. Remove the
obstruction.
Insulation blockage in airlock
exit tube.
Disconnect electrical power.
Remove hose from the machine
outlet. Locate blockage and
remove.
Agitator or airlock bearing may
need replacement.
Have bearing replaced by a
qualified technician.
Circuit breakers need resetting
often.
Low voltage or low amperage.
System requires 115V / 20amp
or 230V / 10amp.
Extension cord gauge is too
small.
Use a 12/3 extension cord with
115V, or a 16A/250V 1.0mm2
extension cord with 230V.
Chain is not aligned with
sprockets.
Disconnect electrical power.
Have a qualified technician
realign chain and sprockets.
Machine makes a banging noise
when agitator is operating.
Chain is loose.
Disconnect electrical power.
Have a qualified technician
adjust chain tensioner.
Adjust chain tensioner.
Chain is not aligned with
sprockets.
Disconnect electrical power.
Have a qualified technician
realign chain and sprockets.